Review





Similar Products

90
Revvity agents angiospark 680
Experimental overview. Ten mRen-rtTAm2/LC-1/tdT mice underwent a 21-day pulse labelling induction period with 625 mg/kg Doxycycline and 10 mg/kg enalapril, followed by a 7-day washout period. (A) Timeline of experimental setup after pulse induction, washout and with abdominal imaging window implantation 72 h before baseline imaging (T0) followed by immediate laser injury irradiation (T1). Longitudinal imaging experiments from all mice were combined and overlapped to cover the entire time period according to the scheme. Each single mouse was imaged longitudinal for 3 h, always with at least 12 h recovery time and only to a maximum of 3 times. (B) Mouse with implanted abdominal imaging window in left flank and visible kidney (red) glued to the inside of the window. (C) Intubated, ventilated and anesthetized mouse on a heating plate fixed via the abdominal imaging window, (D) mounted for intravital two-photon microscopy. (E) Intravital imaged healthy glomerulus and its capillary structures made visible via (I) v . <t>Angiospark</t> <t>680</t> (magenta). (F) Laser-induced injury of the identical glomerulus with Angiospark 680 leakage and white autofluorescence of the laser-injured area. (G) Follow-up of the same laser-irradiated glomerulus 5 days after injury. The autofluorescent area is further visible in the still-functioning glomerulus revealed by Hoechst nuclear staining. (H) Kidney overview of glomeruli positions in three-dimensional intravital imaging data and (I) alignment to identical glomeruli after sacrifice, immunohistology staining and tissue clearing. Guiding laser brandings are marked with green flags in the overlay.
Agents Angiospark 680, supplied by Revvity, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/angiospark+680/AngioSPARK+680+Fluorescent+Imaging+Agent/pmc09550881-35-17-23
Average 90 stars, based on 1 article reviews
agents angiospark 680 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Revvity nev10149
Dyes.
Nev10149, supplied by Revvity, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/angiospark+680/AngioSPARK+680+Fluorescent+Imaging+Agent/pmc08210690-0-3-5
Average 90 stars, based on 1 article reviews
nev10149 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Revvity dye order number supplier purpose application details channel exitation acquisition angiospark 680 nev10149 perkinelmer vessel dye
Dyes.
Dye Order Number Supplier Purpose Application Details Channel Exitation Acquisition Angiospark 680 Nev10149 Perkinelmer Vessel Dye, supplied by Revvity, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/angiospark+680/AngioSPARK+680+Fluorescent+Imaging+Agent/ppr0310090-22-0-13
Average 90 stars, based on 1 article reviews
dye order number supplier purpose application details channel exitation acquisition angiospark 680 nev10149 perkinelmer vessel dye - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Revvity angiospark 680
Dyes.
Angiospark 680, supplied by Revvity, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/angiospark+680/AngioSPARK+680+Fluorescent+Imaging+Agent/pmc07502788-425-2-5
Average 90 stars, based on 1 article reviews
angiospark 680 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
VisEn Medical angiospark 680
Dyes.
Angiospark 680, supplied by VisEn Medical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/angiospark+680/angiospark+680/pmc03332002-388-10-12
Average 90 stars, based on 1 article reviews
angiospark 680 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
VisEn Medical angiospark 680-ivm nanoparticles
Dyes.
Angiospark 680 Ivm Nanoparticles, supplied by VisEn Medical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/angiospark+680/angiospark+680+ivm+nanoparticles/pmc02673852-142-0-3
Average 90 stars, based on 1 article reviews
angiospark 680-ivm nanoparticles - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Experimental overview. Ten mRen-rtTAm2/LC-1/tdT mice underwent a 21-day pulse labelling induction period with 625 mg/kg Doxycycline and 10 mg/kg enalapril, followed by a 7-day washout period. (A) Timeline of experimental setup after pulse induction, washout and with abdominal imaging window implantation 72 h before baseline imaging (T0) followed by immediate laser injury irradiation (T1). Longitudinal imaging experiments from all mice were combined and overlapped to cover the entire time period according to the scheme. Each single mouse was imaged longitudinal for 3 h, always with at least 12 h recovery time and only to a maximum of 3 times. (B) Mouse with implanted abdominal imaging window in left flank and visible kidney (red) glued to the inside of the window. (C) Intubated, ventilated and anesthetized mouse on a heating plate fixed via the abdominal imaging window, (D) mounted for intravital two-photon microscopy. (E) Intravital imaged healthy glomerulus and its capillary structures made visible via (I) v . Angiospark 680 (magenta). (F) Laser-induced injury of the identical glomerulus with Angiospark 680 leakage and white autofluorescence of the laser-injured area. (G) Follow-up of the same laser-irradiated glomerulus 5 days after injury. The autofluorescent area is further visible in the still-functioning glomerulus revealed by Hoechst nuclear staining. (H) Kidney overview of glomeruli positions in three-dimensional intravital imaging data and (I) alignment to identical glomeruli after sacrifice, immunohistology staining and tissue clearing. Guiding laser brandings are marked with green flags in the overlay.

Journal: Frontiers in Physiology

Article Title: A quantitative 3D intravital look at the juxtaglomerular renin-cell-niche reveals an individual intra/extraglomerular feedback system

doi: 10.3389/fphys.2022.980787

Figure Lengend Snippet: Experimental overview. Ten mRen-rtTAm2/LC-1/tdT mice underwent a 21-day pulse labelling induction period with 625 mg/kg Doxycycline and 10 mg/kg enalapril, followed by a 7-day washout period. (A) Timeline of experimental setup after pulse induction, washout and with abdominal imaging window implantation 72 h before baseline imaging (T0) followed by immediate laser injury irradiation (T1). Longitudinal imaging experiments from all mice were combined and overlapped to cover the entire time period according to the scheme. Each single mouse was imaged longitudinal for 3 h, always with at least 12 h recovery time and only to a maximum of 3 times. (B) Mouse with implanted abdominal imaging window in left flank and visible kidney (red) glued to the inside of the window. (C) Intubated, ventilated and anesthetized mouse on a heating plate fixed via the abdominal imaging window, (D) mounted for intravital two-photon microscopy. (E) Intravital imaged healthy glomerulus and its capillary structures made visible via (I) v . Angiospark 680 (magenta). (F) Laser-induced injury of the identical glomerulus with Angiospark 680 leakage and white autofluorescence of the laser-injured area. (G) Follow-up of the same laser-irradiated glomerulus 5 days after injury. The autofluorescent area is further visible in the still-functioning glomerulus revealed by Hoechst nuclear staining. (H) Kidney overview of glomeruli positions in three-dimensional intravital imaging data and (I) alignment to identical glomeruli after sacrifice, immunohistology staining and tissue clearing. Guiding laser brandings are marked with green flags in the overlay.

Article Snippet: Under anesthetic tracheal intubation (isoflurane 1.5%, 0.8 O2 L/min) and after i. v . Injection of fluorescent agents Angiospark 680 (30 μL, undiluted, Perkin&Elmer) and Hoechst 33,342 (50 µL of 2 mg/ml water stock, Sigma-Aldrich), all mice were prepared for upright imaging on a heating plate with a custom-made abdominal imaging window holder ( ).

Techniques: Imaging, Irradiation, Microscopy, Staining

Representative data of glomerular perfusion before, during and after laser irradiation. (A) Representative glomerulus in white circle at four time-points healthy at T0 and (B) immediately after laser irradiation (white arrow) at T1. (C) Identical glomerulus 15 min after laser irradiation at T1 with visible Angiospark 680 leakage and (D) at experiment endpoint 96 h after T0. (E) Time-points (A–D) from three glomeruli of three different animals derived image deviation as a quantifiable surrogate parameter for glomerular perfusion. Image deviation data was compared with two-way ANOVA tests and Tukey’s multiple comparisons test calculated individual mean ± SD values. White scale bars represent 10 µm.

Journal: Frontiers in Physiology

Article Title: A quantitative 3D intravital look at the juxtaglomerular renin-cell-niche reveals an individual intra/extraglomerular feedback system

doi: 10.3389/fphys.2022.980787

Figure Lengend Snippet: Representative data of glomerular perfusion before, during and after laser irradiation. (A) Representative glomerulus in white circle at four time-points healthy at T0 and (B) immediately after laser irradiation (white arrow) at T1. (C) Identical glomerulus 15 min after laser irradiation at T1 with visible Angiospark 680 leakage and (D) at experiment endpoint 96 h after T0. (E) Time-points (A–D) from three glomeruli of three different animals derived image deviation as a quantifiable surrogate parameter for glomerular perfusion. Image deviation data was compared with two-way ANOVA tests and Tukey’s multiple comparisons test calculated individual mean ± SD values. White scale bars represent 10 µm.

Article Snippet: Under anesthetic tracheal intubation (isoflurane 1.5%, 0.8 O2 L/min) and after i. v . Injection of fluorescent agents Angiospark 680 (30 μL, undiluted, Perkin&Elmer) and Hoechst 33,342 (50 µL of 2 mg/ml water stock, Sigma-Aldrich), all mice were prepared for upright imaging on a heating plate with a custom-made abdominal imaging window holder ( ).

Techniques: Irradiation, Derivative Assay

Dyes.

Journal: F1000Research

Article Title: A new analysis approach for single nephron GFR in intravital microscopy of mice

doi: 10.12688/f1000research.26888.3

Figure Lengend Snippet: Dyes.

Article Snippet: AngioSPARK 680 , NEV10149 , PerkinElmer , Vessel dye , 30 µl , 3 , 860 nm , 685–695 nm.

Techniques: